Fyrewash F3 Flyer

Rochem ®is the only companyin the world that
designs, manufactures, markets and supports its own
systems and chemicals on a worldwide basis

The FYREWASH® System has been incorporated by leading gas turbine manufacturers and packagers, such as: STEWART & STEVENSONGas Turbine Division (Houston, Texas), JOHN BROWN ENGINEERING(London, England), GENERAL ELECTRIC (Schenectady, New York), FIAT(Italy), EUROPEAN GAS TURBINES(Lincoln, England) and other major OEM's.

For almost 35 years in manufacturing & bussiness,
with the excess of 8000 systems installed world-wide
on every type of gas turbines

An average 46,500kW gas turbine with normal fouling & showing a 3% power decrease & 1% heat rate increase can suffer a loss of performance costing more than $500,000 every year.

 Understanding our customers’ need to keep their engines operational at the highest possible output and lowest possible cost, Rochem Technical Services offers a range of On-crank (crankwash) and On-line (Fired Wash)
engine cleaning systems and chemicals.

FYREWASH F3Chemical is a range of specialist compressor cleaning chemicals with outstanding performance designed for all types of fouling & meets current OEM & environmental standards worldwide

HEALTH & SAFETY
 Fyrewash F3 is not classified as toxic, hazardous or irritants.
-The following precautionary advice appears in the Safety Data Sheets. Wash off all splashes. Wear rubber gloves if sustained contact is likely. Wear goggles if spraying.
ENVIRONMENTAL
Biodegradable
Environmental precautions:
Dilute with plenty of water
 Do not allow to enter sewers/surface or ground water
Methods and material for containment and cleaning up:
-­‐Absorb with liquid-­‐binding material (sand, diatomite, acid
binders, universal binders, sawdust)
-­‐ Ensure adequate ventilation
LOGISTICS
SAFETY AND HANDLING
HAZARDS: EC Hazard rating: Xi. Irritant
US NFPA rating: 1,1,0
PROTECTIVE MEASURES: Non-­‐hazardous but avoid frequent
prolonged direct contact with skin to prevent possibility of de-­‐
oiling skin and wear eye protection as a matter of course when
handling any chemical.
SPILLAGE: Absord large spillages with sand or earth. Flush away
small spillages with water
FIRE: Use foam, carbon dioxide, dry chemicals, sand or earth.
MANAGEMENT SYSTEMS
PACKAGING:
25 lt (6.5 USG) pails, 210 lt (55 USG)
drums & 1000 lt International Bulk
Container (IBC)
Container of 200 Lint-­‐free wipes
SHIPPING:
No restrictions. Classi+ied as non-­‐
hazardous for international transport by
road, sea and air
STORAGE:
Store in a cool, dry place in tightly closed

SAFETY AND HANDLING

HAZARDS: EC Hazard rating: Xi. Irritant
US NFPA rating: 1,1,0
PROTECTIVE MEASURES: Non-­‐hazardous but avoid frequent
prolonged direct contact with skin to prevent possibility of de-­‐
oiling skin and wear eye protection as a matter of course when
handling any chemical.
SPILLAGE: Absord large spillages with sand or earth. Flush a

Apearance: Clear liquid
Shelf life: 5 years
pH (20% solution): 7 – 7.5
Flash point: no plash point
Melting point: -­‐15°C
Flammability: Not applicable
Application: FYREWASH F3 can be used with any on-­‐line/
off-­‐line injection system but for optimum cleaning results
and economic usage of chemicals, Rochem offers a full range
of patented manual or fully automatic atomising injection
systems to suit any engine type.
FYREWASH F3 can be used without dilution for of+line
cleaning, providing a superb cleaning result for heavily
fouled compressors.
Dilution: 1 to 4 with water before use (20% solution)
Fyrewash F3-­‐Super Concentrate version is to be mixed in a
1:19 dilution.
Use demineralised water as speci+ied by the engine
manufacturer, typically < 11

Liên quan