{"id":997,"date":"2014-06-28T03:56:52","date_gmt":"2014-06-28T03:56:52","guid":{"rendered":"http:\/\/13.215.197.123\/?p=997"},"modified":"2014-06-28T03:56:52","modified_gmt":"2014-06-28T03:56:52","slug":"fyrewash-f3-flyer","status":"publish","type":"post","link":"https:\/\/rochem.vn\/index.php\/fyrewash-f3-flyer\/","title":{"rendered":"Fyrewash F3 Flyer"},"content":{"rendered":"<table style=\"width: 750px;\" cellspacing=\"14\">\n<tbody>\n<tr>\n<td style=\"vertical-align: top;\">\n<p><span><span style=\"line-height: 24px;\"><span style=\"color: #2b2b2b; font-family: Lato, sans-serif; font-size: medium;\">Rochem \u00aeis the only companyin the world that <br \/>designs, manufactures, markets and supports its own <br \/>systems and chemicals on a worldwide basis<\/span><\/span><\/span><\/p>\n<p>The FYREWASH\u00ae System has been incorporated by leading gas turbine manufacturers and packagers, such as: STEWART &amp; STEVENSONGas Turbine Division (Houston, Texas), JOHN BROWN ENGINEERING(London, England), GENERAL ELECTRIC (Schenectady, New York), FIAT(Italy), EUROPEAN GAS TURBINES(Lincoln, England) and other major OEM&#8217;s.<\/p>\n<p>For almost 35 years in manufacturing &amp; bussiness, <br \/>with the excess of 8000 systems installed world-wide <br \/>on every type of gas turbines<\/p>\n<p>An average 46,500kW gas turbine with normal fouling &amp; showing a 3% power decrease &amp; 1% heat rate increase can suffer a loss of performance costing more than $500,000 every year.<\/p>\n<p>\u00a0Understanding our customers\u2019 need to keep their engines operational at the highest possible output and lowest possible cost, Rochem Technical Services offers a range of On-crank (crankwash) and On-line (Fired Wash) <br \/>engine cleaning systems and chemicals.<\/p>\n<p>FYREWASH F3Chemical is a range of specialist compressor cleaning chemicals with outstanding performance designed for all types of fouling &amp; meets current OEM &amp; environmental standards worldwide<\/p>\n<\/td>\n<td style=\"width: 370px; vertical-align: top;\">\n<p><span><span style=\"line-height: 24px;\"><span style=\"color: #2b2b2b; font-family: Lato, sans-serif; font-size: medium;\">HEALTH &amp; SAFETY<br \/>\u00a0Fyrewash F3 is not classified as toxic, hazardous or irritants.<br \/>-The following precautionary advice appears in the Safety Data Sheets. Wash off all splashes. Wear rubber gloves if sustained contact is likely. Wear goggles if spraying.<br \/>ENVIRONMENTAL<br \/>Biodegradable<br \/>Environmental precautions:<br \/>Dilute with plenty of water<br \/>\u00a0Do not allow to enter sewers\/surface or ground water<br \/>Methods and material for containment and cleaning up: <br \/>-\u00ad\u2010Absorb with liquid-\u00ad\u2010binding material (sand, diatomite, acid <br \/>binders, universal binders, sawdust)<br \/>-\u00ad\u2010 Ensure adequate ventilation<br \/>LOGISTICS<br \/>SAFETY AND HANDLING<br \/>HAZARDS: EC Hazard rating: Xi. Irritant<br \/> US NFPA rating: 1,1,0<br \/>PROTECTIVE MEASURES: Non-\u00ad\u2010hazardous but avoid frequent <br \/>prolonged direct contact with skin to prevent possibility of de-\u00ad\u2010<br \/>oiling skin and wear eye protection as a matter of course when <br \/>handling any chemical.<br \/>SPILLAGE: Absord large spillages with sand or earth. Flush away <br \/>small spillages with water<br \/>FIRE: Use foam, carbon dioxide, dry chemicals, sand or earth.<br \/>MANAGEMENT SYSTEMS<br \/>PACKAGING:<br \/>25 lt (6.5 USG) pails, 210 lt (55 USG) <br \/>drums &amp; 1000 lt International Bulk <br \/>Container (IBC)<br \/>Container of 200 Lint-\u00ad\u2010free wipes<br \/>SHIPPING:<br \/>No restrictions. Classi+ied as non-\u00ad\u2010<br \/>hazardous for international transport by <br \/>road, sea and air<br \/>STORAGE:<br \/>Store in a cool, dry place in tightly closed<\/span><\/span><\/span><\/p>\n<p><span style=\"color: #2b2b2b; font-family: Lato, sans-serif; font-size: medium;\"><span style=\"line-height: 24px;\">SAFETY AND HANDLING<\/span><\/span><\/p>\n<p><span style=\"color: #2b2b2b; font-family: Lato, sans-serif; font-size: medium;\"><span style=\"line-height: 24px;\"><span>HAZARDS: EC Hazard rating: Xi. Irritant<\/span><br \/><span> US NFPA rating: 1,1,0<\/span><br \/><span>PROTECTIVE MEASURES: Non-\u00ad\u2010hazardous but avoid frequent <\/span><br \/><span>prolonged direct contact with skin to prevent possibility of de-\u00ad\u2010<\/span><br \/><span>oiling skin and wear eye protection as a matter of course when <\/span><br \/><span>handling any chemical.<\/span><br \/><span>SPILLAGE: Absord large spillages with sand or earth. Flush a<\/span><\/span><\/span><\/p>\n<p>Apearance: Clear liquid <br \/>Shelf life: 5 years<br \/>pH (20% solution): 7 \u2013 7.5<br \/>Flash point: no plash point<br \/>Melting point: -\u00ad\u201015\u00b0C<br \/>Flammability: Not applicable<br \/>Application: FYREWASH F3 can be used with any on-\u00ad\u2010line\/<br \/>off-\u00ad\u2010line injection system but for optimum cleaning results <br \/>and economic usage of chemicals, Rochem offers a full range <br \/>of patented manual or fully automatic atomising injection <br \/>systems to suit any engine type.<br \/>FYREWASH F3 can be used without dilution for of+line <br \/>cleaning, providing a superb cleaning result for heavily <br \/>fouled compressors.<br \/>Dilution: 1 to 4 with water before use (20% solution)<br \/>Fyrewash F3-\u00ad\u2010Super Concentrate version is to be mixed in a <br \/>1:19 dilution.<br \/>Use demineralised water as speci+ied by the engine <br \/>manufacturer, typically &lt; 11<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Rochem \u00aeis the only companyin the world that designs, manufactures, markets and supports its own systems and chemicals on a worldwide basis The FYREWASH\u00ae System has been incorporated by leading gas turbine manufacturers and packagers, such as: STEWART &amp; STEVENSONGas Turbine Division (Houston, Texas), JOHN BROWN ENGINEERING(London, England), GENERAL ELECTRIC (Schenectady, New York), FIAT(Italy), EUROPEAN [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-997","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/rochem.vn\/index.php\/wp-json\/wp\/v2\/posts\/997","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rochem.vn\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/rochem.vn\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/rochem.vn\/index.php\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/rochem.vn\/index.php\/wp-json\/wp\/v2\/comments?post=997"}],"version-history":[{"count":1,"href":"https:\/\/rochem.vn\/index.php\/wp-json\/wp\/v2\/posts\/997\/revisions"}],"predecessor-version":[{"id":1014,"href":"https:\/\/rochem.vn\/index.php\/wp-json\/wp\/v2\/posts\/997\/revisions\/1014"}],"wp:attachment":[{"href":"https:\/\/rochem.vn\/index.php\/wp-json\/wp\/v2\/media?parent=997"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/rochem.vn\/index.php\/wp-json\/wp\/v2\/categories?post=997"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/rochem.vn\/index.php\/wp-json\/wp\/v2\/tags?post=997"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}