Drinking Water From The Sea
RO-MEMBRANE FILTRATION UNITS
Designed and constructed for continuous operation to desalt and purify:
|
With comprehensive standard features
Necessary feature such as filter booster pump, filtration package, inbuilt cleaning system, automatic pressure regulation, flow control, full instrumentation and fail-safe protection are fitted as standard – not as expensive ‘options’ as in the case of many other systems. With additional facilitiesThe basic system design allows for a building block concept or modular expansion to incorporate-either at the factory or as a later retrofit-additional facilities to meet the changing needs of the operator. For example, raw water pre-heaters can be included with no modifications to the basic system. Carbon filters, pure water distribution systems, ultra violet and/or chlorine dosing systems etc. can also be easily interfaced with the basic system. Plus low-cost maintenance, operation and serviceModular construction and purpose-designed clear access to all major components and piping means that inspection and preventive maintenance can be carried out quickly and effectively. Automatic operation and regulation of the system, fail-safe design and fault indication facilities ensure correct, safe and reliable operation of the system. A fully documented computer ‘history’ with details of all component parts used is developed for each system produced and a comprehensive spare parts and consumables inventory is maintained by Rochem to provide the operator with a quick response after-sales service. Based wide range of standard systemsWith 10 different capacities up to 350000 litres/ 24 hours for sea water application and a similar number up to 500000 litres/ 24 hours for brackish water, Rochem can usually meet at short notice most customer requirements from its standard range. If not, larger capacity systems or more specialized systems are available on request. And installed and operational in a matter of hoursSince every Rochem RO system is completely assembled and fully tested prior to dispatch from the factory and can be in full operation literally just a few hours after arriving on site. There are only four fixed or flexible pipe connections to make plus an electrical supply. Nothing else. |
|
List of standard components
|
Optional Equipment
|
A - Municipal Water Treatment | B - Brackish Water Desalination | C - Sea Water Desalination | ||||||
Recovery: 75% Operating pressure: 40 bar | Recovery: 50% Operating pressure: 40-50 bar | Recovery: 30% Operating pressure: 60 bar | ||||||
Feedwater | Purewater | Feedwater | Purewater | Feedwater | Purewater | |||
Conduct. | 753 µS/cm | 13 µS/cm | Conduct. | 14190 µS/cm | 193 µS/cm | Conduct. | 48900 µS/cm | 920 µS/cm |
TDS | 665 ppm | 6,0 ppm | TDS | 8,898 ppm | 104 ppm | TDS | 34340 ppm | 400 ppm |
Na | 49 ppm | 1,3 ppm | Na | 2368 ppm | 39 ppm | Na | 9,600 ppm | 140 ppm |
K | 5,8 ppm | 0,1 ppm | K | 80 ppm | 2 ppm | K | 34 ppm | 0,8 ppm |
Ca | 113 ppm | 0,4 ppm | Ca | 107 ppm | 0,24 ppm | Ca | 327 ppm | 1,6 ppm |
Mg | 10,6 ppm | 0,04 ppm | Mg | 294 ppm | 0,48 ppm | Mg | 1360 ppm | 3,4 ppm |
Cl | 142 ppm | 3,3 ppm | Cl | 4320 ppm | 61 ppm | Cl | 20210 ppm | 201 ppm |
SO4 | 106 ppm | - | SO4 | 607 ppm | - | SO4 | 2,590 ppm | 2,4 ppm |
Si | 25 ppm | 0,3 ppm | Si | 0,3 ppm | - | Si | 0,1 ppm | - |