Reverse Osmosis Application for Metal Finishing Operations

Merit Partnership Pollution Prevention Project for Metal Finishers

Galaya Srisuwan, and Poonpetch Thongchai

RO applications for electroplating operations were mostly limited to final treatment of a combined wastewater stream. Such applications typically involved discharging the permeate to a POTW and returning the concentrate to the head of the wastewater treatment system. Because of the high flow rates associated with treating combined wastewater streams, large, RO units were required. More recent metal finishing applications of RO have involved installing RO units in specific process operations, allowing return of the concentrate (recovered chemical solution) to the process bath and reuse of the permeate (cleaned rinse water) as fresh rinse water. By “closing the loop”, valuable process chemicals are recovered, and less fresh water is needed. Furthermore, a waste stream is eliminated that would otherwise be discharged to the POTW.
 
electroplating Proven RO Applications:
  • Copper Electroplating
  • Nickel Electroplating
  • Zinc Electroplating
  • Nickel Acetate Seal
  • Black Dye
  The heavy metal removal efficiency of RO of synthetic electroplating wastewater of four processes of chromium, copper, nickel and zinc electroplating , each was higher than that from factory wastewater but slightly lower than the removal efficiency obtained from composite synthetic wastewater.
Table 1. Industrial electroplating wastewater characteristics.
Parameter Chrome rinsed Copper rinsed Nickel rinsed Zinc rinsed
Heavy Metals(mg/l) 2,136 1,020 96.1 8.7
pH 1.66 1.76 5.21 7.60
Conductivity (mS/cm) 30.00 8.12 1.15 1.00
TS (mg/l) 6,130 3,470 530 1,370
SS (mg/l) 12 4 3 4
TDS (mg/l) 6,118 3,466 527 1,366
 
  Heavy metals are important sources of environmental pollution. Some of them can form compounds which are toxic even in very low concentration. Even though the conventional techniques for organic compounds removal are biological and chemical treatment of the toxic materials degrades them to salts and CO2, the metals are permanent. The only way to remove them is to change their chemical and physical states by oxidation/reduction and precipitation. So far, there have been a number of researches that studied physical and chemical treatments.   Membrane technology was one option for a nonpolluting process. The membrane of optimum pore sizes were capable of removing almost all pollutants without using any chemicals. Sludge obtained in the process contained only pollutant constituents in this feed stream. In order to increase the removal efficiency and reduce the operating cost, membrane technology was also used together with other treatment processes .
  electroplating
Key words: membrane, RO, heavy metals, electroplating, wastewater.